Skip to main content Skip to search Skip to main navigation

Frogger Free Play and High Score Save Kit Settings Menu Video

Watch the official HighScoreSaves settings menu video guide for the Frogger Free Play and High Score Save Kit. Learn how to access the settings menu and configure Free Play, high score saving, Stealth Mode, separate score tables and supported operator settings for compatible original Konami and Sega/Gremlin Frogger arcade PCBs.

About This Frogger Settings Menu Video

This official HighScoreSaves settings menu video guide demonstrates the configuration options available with the Frogger Free Play and High Score Save Kit. Designed for compatible original Konami and Sega/Gremlin arcade hardware, the kit retains classic Frogger gameplay while adding modern operator settings and permanent high score storage.

This video focuses on settings menu access and configuration rather than physical daughterboard installation.

Frogger Free Play and High Score Save Kit Settings

Supported kit features and configuration options include:

  • Free Play or traditional coin operation
  • Permanent Top 5 high score saving with player initials
  • Battery-free high score storage
  • Separate high score tables for 2, 3 and 4 lives
  • On-screen game and DIP-switch settings
  • High score Backup and Restore
  • Stealth Mode
  • Selectable attract-screen and logo options
  • Optional ROM Saver functionality
  • Optional Wi-Fi leaderboard support

Free Play, local high score saving and supported game settings do not require an internet connection. Online leaderboard functionality requires the Wi-Fi Enabled version and appropriate network configuration.

Accessing the Frogger Settings Menu

How to enter the settings menu:

  1. Turn off your arcade cabinet.
  2. Hold Player 1 Start while powering on the cabinet.
  3. Continue holding Player 1 Start for approximately four seconds, until the on-screen prompt appears.
  4. Release Player 1 Start when instructed on screen.

Use your original arcade controls to navigate the available menu options. Refer to the video and official installation guide for additional information.

Having Trouble Accessing the Settings Menu?

Turn off the cabinet, verify that Player 1 Start operates correctly and repeat the power-on procedure. Refer to the installation guide for additional information about supported menu-entry settings.

Frogger Stealth Mode

Stealth Mode allows arcade owners to maintain an appearance closer to the original Frogger game during normal operation while retaining access to the HighScoreSaves settings menu.

This option is useful for collectors who want modern kit functionality without unnecessarily changing the classic arcade presentation.

Frogger High Score Saving

The HighScoreSaves kit uses battery-free serial EEPROM storage to retain the Top 5 supported high scores and player initials after cabinet power is switched off.

Independent score tables are maintained for supported two-, three- and four-life configurations. The Backup and Restore functions allow players to preserve and retrieve supported high score data through the settings menu.

Frogger Arcade PCB Compatibility

Original Konami and Sega/Gremlin Frogger Hardware

  • Documented compatible original Konami or Sega/Gremlin Frogger arcade PCB
  • Documented 36-pin edge connector
  • Compatible Z80 processor on the lower PCB of the original board stack
  • Compatible 40-pin Z80 CPU socket required
  • Supports compatible upright and cocktail installations
  • No soldering required when the original Z80 is already socketed
  • Original program ROM removal is optional

The HighScoreSaves daughterboard installs at the original Z80 processor location. Additional board-stack clearance may be necessary, depending on the existing spacer configuration. Follow the official installation guide to verify processor orientation, daughterboard placement and clearance before restoring cabinet power.

Important Compatibility Information

This settings menu video applies specifically to the HighScoreSaves Frogger Free Play and High Score Save Kit. The Braze Technologies Frogger kit is a separate product with its own settings, diagnostics and installation requirements. Always follow the documentation for your installed kit.

Frogger Installation & Helpful Resources

Review the official product page, PCB compatibility information and installation guide before ordering or installing your kit.

View Frogger Free Play and High Score Save Kit Explore kit features, Standard and Wi-Fi versions, available options, pricing and ordering information. Compare Frogger Kits and PCB Compatibility Compare HighScoreSaves and Braze Frogger upgrade options, original hardware requirements and installation differences. View Frogger Installation Guide PDF Official installation instructions covering original Frogger PCB identification, Z80 orientation, daughterboard placement, board-stack clearance and settings access. How to Identify Your Original Arcade PCB Learn how to identify your original Frogger arcade hardware before selecting a compatible upgrade kit.

Additional Video & Installation Resources

Watch Frogger Settings Menu Video on YouTube Open the original HighScoreSaves Frogger settings menu video on YouTube. Browse All High Score Save Kit Settings Video Guides Explore additional official HighScoreSaves settings menu demonstrations. Browse All Arcade Kit Installation Guides Find official printable installation documentation for HighScoreSaves arcade kits.
Official HighScoreSaves Settings Menu Video Guide

Original arcade PCB upgrades since 2015.